EasyManuals Logo

Vivotek FD8168 User Manual

Vivotek FD8168
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #169 background imageLoading...
Page #169 background image
VIVOTEK
User's Manual - 169
49
trigger boot,
motion,
seq,
recnotify,
tampering,
vi,
volalarm
boot 6/6 Indicate the trigger condition:
“boot” = System boot
“motion” = Video motion detection
“seq” = Periodic condition
“recnotify” = Recording notification.
“tampering” = Tamper detection.
“vi”= Virtual input (Manual trigger)
“volalarm” = Audio detection.
triggerstatus String[40] triggerstatus 6/6 The status for event trigger
vi <integer> 0 6/6 Indicate the source id of vi trigger.
This field is required when trigger
condition is “vi”.
One bit represents one digital input.
The LSB indicates VI 0.
mdwin <integer> 0 6/6 Indicate the source window id of
motion detection.
This field is required when trigger
condition is “md”.
One bit represents one window.
The LSB indicates the 1
st
window.
For example, to detect the 1
st
and 3
rd
windows, set mdwin as 5.
mdwin0 <integer> 0 6/6 Similar to mdwin. The parameter
takes effect when profile 1 of motion
detection is enabled.
inter 1~999 1 6/6 Interval of snapshots in minutes.
This field is used when trigger
condition is “seq”.

Table of Contents

Other manuals for Vivotek FD8168

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vivotek FD8168 and is the answer not in the manual?

Vivotek FD8168 Specifications

General IconGeneral
BrandVivotek
ModelFD8168
CategorySecurity Camera
LanguageEnglish

Related product manuals