VIVOTEK
174 - User's Manual
59
certificate manually.
install => Create certificate
request and install.
status -3 ~ 1 0 6/6 Specify the https status.
-3 = Certificate not installed
-2 = Invalid public key
-1 = Waiting for certificate
0 = Not installed
1 = Active
countryname string[2] TW 6/6 Country name in the certificate
information.
stateorprovincename string[128] Asia 6/6 State or province name in the
certificate information.
localityname string[128] Asia 6/6 The locality name in the
certificate information.
organizationname string[64] VIVOTEK
Inc.
6/6 Organization name in the
certificate information.
unit string[64] VIVOTEK
Inc.
6/6 Organizational unit name in the
certificate information.
commonname string[64] www.vivotek
.com
6/6 Common name in the certificate
information.
validdays 0 ~ 3650 3650 6/6 Valid period for the
certification.
7.28 Storage management setting
Currently it’s for local storage (SD card)
Group: disk_i<0~(n-1)> n is the total number of storage devices.
PARAMETER VALUE Default SECURITY
(get/set)
DESCRIPTION
cyclic_enabled <boolean> 0 6/6 Enable cyclic storage method.
autocleanup_enabled <boolean> 0 6/6 Enable automatic clean up method.
Expired and not locked media files
will be deleted.
autocleanup_maxage 1~<positive
integer>
7 6/6 To specify the expired days for
automatic clean up.