176 - User's Manual
61
patrolseq string[120] <blank> 1/4 The patrol sequence of ePTZ. All the
patrol position indexes will be
separated by ","
patroldwelling string[160] <blank> 1/4 The dwelling time (unit: second) of
each patrol point, separated by “,”.
preset_i<0~19>_name string[40] <blank> 1/7 Name of ePTZ preset.
(It should be set by ePreset.cgi rather
than by setparam.cgi.)
preset_i<0~19>_pos <coordinate> <blank> 1/7 Left-top corner coordinate of the
preset.
(It should be set by ePreset.cgi rather
than by setparam.cgi.)
preset_i<0~19>_size <window size> <blank> 1/7 Width and height of the preset.
(It should be set by ePreset.cgi rather
than by setparam.cgi.)
7.31 Exposure window setting per channel
Group: exposurewin_c<0~(n-1)> for n channel products
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
mode auto, custom,
blc
auto 4/4 The mode indicates
how to decide the
exposure.
auto: Use full view
as the only one
exposure window.
custom: Use
inclusive and
exclusive window.
blc: Use BLC.
win_i<0~9>_enable <boolean> 0 4/4 Enable or disable the
window.
win_i<0~9>_policy 0~1 0 4/4 0: Indicate
exclusive.
1: Indicate inclusive.
win_i<0~9>_home <coordinate> 110,90 4/4 Left-top corner
coordinate of the
window.