value.
- (ranged) : UI is fixed to multiple
selections or values.
- (enabled) : UI is checked.
- (notsupport) : the affected function
is not available.
"Affect API name" can be described in
hierarchy, such as
"exposurewin.mode.blc:disabled:"
which means blc exposure window is
disabled. API name can be one word as
well, such as "exposurelevel:fixed:6"
which means exposurelevel is fixed to
level 6.
"Description" can be a nonnegative
integer or string or NULL.
"-" means no feature is affected.
* Only available when qualitypriority is
listed in
"capability_image_c<0~(n-1)>_
exposure_modetype" and
"capability_image_c<0~(n-1)>_
exposure_mode" is 1.
* We support this parameter when the
version number (httpversion) is equal
or greater than 0305a.
exposure_manualmode_a
ffect
-,
exposurewin.mode.blc:hidd
en:,
defog:disabled:,
wdrpro:disabled:,
exposurelevel:hidden:,
or others
<x>: nonnegative integer
<product dependent>
0/7 When exposure manual mode is
enabled, some features may become
malfunction or be forced to a given
value. The affected functions are list
here.
The format is "Affect API
name":"Policy":"Description"
"Policy" can be categorized into
following groups:

Other manuals for Vivotek FD8366-V