EasyManuals Logo

Vivotek FD836B-(E)HVF2 User Manual

Vivotek FD836B-(E)HVF2
315 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #56 background imageLoading...
Page #56 background image
VIVOTEK
56 - User's Manual
Exposure
On this page, you can set the Exposure measurement window, Exposure level, Exposure mode,
Exposure time, Gain control, and Day/Night mode settings. You can congure two sets of Exposure
settings: one for normal situations, the other for special situations, such as the day/night/schedule
mode.
Sensor Setting 1:
For normal situations
Sensor Setting 2:
For special situations
Measurement Window: This function allows users to set measurement window(s) for low light
compensation. For example, where low-light objects are posed against an extremely bright
background. You may want to exclude the bright sunlight shining through a building's corridor.
■ Full view: Calculate the full range of view and offer appropriate
light compensation.
Custom: This option allows you to manually add customized windows as inclusive or exclusive
regions. A total of 10 windows can be configured. Please refer to the next page for detailed
illustration.

Table of Contents

Other manuals for Vivotek FD836B-(E)HVF2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vivotek FD836B-(E)HVF2 and is the answer not in the manual?

Vivotek FD836B-(E)HVF2 Specifications

General IconGeneral
BrandVivotek
ModelFD836B-(E)HVF2
CategorySecurity Camera
LanguageEnglish

Related product manuals