EasyManua.ls Logo

Vivotek FD9369 - Page 212

Vivotek FD9369
427 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VIVOTEK
212 - User's Manual
© 2020 VIVOTEK INC. All Right Reserved
88
NAME VALUE SECURITY
(get/set)
DESCRIPTION
_mode" = 1
2: Enable WDR Pro II.
* Only valid when
"capability_image_c<0~(n-1)>_wdrpro
_mode" = 2
wdrpro_streng
th
<product
dependent>
1~100 4/4 The strength of WDR Pro.
The bigger value means the stronger
strength of WDR Pro.
* Only available when
"capability_image_c<0~(n-1)>_wdrpro
_strength" is 1
wdrc_mode
<product
dependent>
<boolean> 4/4 Enable WDR enhanced.
* Only available when
"capability_image_c<0~(n-1)>_wdrc_
mode" is 1
wdrc_strength
<product
dependent>
1~100 4/4 The strength of WDR enhanced.
The bigger value means the stronger
strength of WDR enhanced.
* Only available when
"capability_image_c<0~(n-1)>_wdrc_
mode" is 1
aespeed_mod
e
<product
dependent>
<boolean> 4/4 Turning AE converge speed on or off.
0: off
1: on
* Only available when
"capability_image_c<0~(n-1)>_aespee
d" is 1
aespeed_spee
dlevel
<product
dependent>
1~100 4/4 The speed level of AE converge speed.
1~20: level 1
21~40: level 2
41~60: level 3
61~80: level 4
81~100: level 5
Level 1~4(low ~ high)
The higher speed level meas shorter
AE converged time during AE