EasyManua.ls Logo

Vivotek FD9391-EHTV - Page 166

Vivotek FD9391-EHTV
369 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VIVOTEK
166 - User's Manual
7.3 Digital input behavior define
Group: di_i<0~(n-1)> for n is the value of "capability_ndi" (capability.ndi > 0)
NAME VALUE SECURITY
(get/set)
DESCRIPTION
normalstate high,
low
1/1 Indicates open circuit or closed circuit
(inactive status)
7.4 Digital output behavior define
Group: do_i<0~(n-1)> for n is the value of "capability_ndo" (capability.ndo > 0)
NAME VALUE SECURITY
(get/set)
DESCRIPTION
normalstate open,
grounded
1/1 Indicate open circuit or closed circuit (inactive
status)
7.5 Security
Group: security
NAME VALUE SECURITY
(get/set)
DESCRIPTION
privilege_do view, operator,
admin
1/6 Indicate which privileges and above can
control digital output
(capability.ndo > 0)
privilege_camctrl view, operator,
admin
1/6 Indicate which privileges and above can
control PTZ
(capability.ptzenabled > 0 or capability.eptz >
0)
user_i0_name string[64] 6/7 User name of root
user_i<1~20>_name string[64] 6/7 User name
user_i0_pass password[64] 7/6 Root password
user_i<1~20>_pass password[64] 7/6 User password
user_i0_privilege view,
operator,
admin
6/7 Root privilege
user_i<1~20>_ privilege view,
operator,
admin
6/6 User privilege

Other manuals for Vivotek FD9391-EHTV

Related product manuals