EasyManua.ls Logo

Vivotek IB8367 - Page 150

Vivotek IB8367
230 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VIVOTEK
150 - User's Manual
18
7.2 status
Group: status
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
di_i<0~(ndi-1)> <boolean> 0 1/7 0 => Inactive, normal
1 => Active, triggered
do_i<0~(ndo-1)> <boolean> 0 1/7 0 => Inactive, normal
1 => Active, triggered
daynight day, night 0 7/7 Current status of day, night.
onlinenum_rtsp integer 0 6/7 Current number of RTSP
connections.
onlinenum_httppush integer 0 6/7 Current number of HTTP push
server connections.
eth_i0 <string> <blank> 1/7 Get network information from
mii-tool.
vi_i<0~(nvi-1)> <boolean> 0 1/7 Virtual input
0 => Inactive
1 => Active
7.3 digital input behavior define
Group: di_i<0~(ndi-1)>
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
normalstate high,
low
high 1/1 Indicates open circuit or
closed circuit (inactive
status)
7.4 digital output behavior define
Group: do_i<0~(ndo-1)>
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
Normalstate open,
grounded
open 1/1 Indicate open circuit or
closed circuit (inactive
status)