Vivotek IP7138 - Digital Output Control

Vivotek IP7138
123 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VIVOTEK - A Leading Provider of Multimedia Communication Solutions
User's Manual - 111
redirect to https connection
method auto,
manual,
install
6/6
auto => Create self-signed certificate automatically
manual => Create self-signed certificate manually
install => Create certificate request and install
status -2 ~ 1 6/6 Specify the https status.
-2=>invalid public key
-1=>waiting for certificated
0=>not installed
1=>active
countryname string[2] 6/6 country name in certificate information
stateorprovincename string[128] 6/6 state or province name in in certificate
information
localityname string[128] 6/6 the locality name in certificate information
organizationname string[64] 6/6 organization naem in certificate information
unit string[32] 6/6 organizational unit name in certificate
information
commonname string[64] 6/6 common name in certificate information
validdays 0 ~ 9999 6/6 certificatation valid period
Drive the digital output
Note: This request requires the privilege of viewer.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/dido/setdo.cgi?do1=<state>[&do2=<state>]
[&do3=<state>][&do4=<state>][&return=<return page>]
Where state is 0, 1. “0” means inactive or normal state while “1” means active or triggered state.
PARAMETER VALUE DESCRIPTION
0 – inactive, normal state
do<num>
0, 1
1 – active, triggered state
return
<return page> Redirect to the page <return page> after the parameter is
assigned. The <return page> can be a full URL path or relative
path according the the current path. If you omit this parameter,
it will redirect to an empty page.