NOTE: The camera should prevent to restart when parameter changed.
Group: system
NAME VALUE SECURITY
(get/set)
DESCRIPTION
hostname string[40] 1/6 host name of server
(Network Camera,
Wireless Network Camera,
Video Server,
Wireless Video Server)
ledoff <boolean> 6/6 turn on(0) or turn off(1) all led
indicators
date <yyyy/mm/dd>,
keep,
auto
6/6 Current date of system. Set to ‘keep’
keeping date unchanged. Set to ‘auto’
to use NTP to synchronize date.
time <hh:mm:ss>,
keep,
auto
6/6 Current time of system. Set to ‘keep’
keeping time unchanged. Set to ‘auto’
to use NTP to synchronize time.
datetime <MMDDhhmmYYYY.ss> 6/6 Another current time format of system.
ntp <domain name>,
<ip address>,
<blank>
6/6 NTP server
*do not use “skip to invoke default
server” for default
timezoneindex -489 ~ 529 6/6 Indicate timezone and area
-480: GMT-12:00 Eniwetok, Kwajalein
-440: GMT-11:00 Midway Island,
Samoa
-400: GMT-10:00 Hawaii
-360: GMT-09:00 Alaska
-320: GMT-08:00 Las Vegas,
San_Francisco, Vancouver
-280: GMT-07:00 Mountain Time,
Denver
-281: GMT-07:00 Arizona
-240: GMT-06:00 Central America,
Central Time, Mexico City,
Saskatchewan
-200: GMT-05:00 Eastern Time, New
York, Toronto
-201: GMT-05:00 Bogota, Lima, Quito,
Indiana