VIVOTEK
102 - User's Manual
Group: ipfilter
NAME VALUE SECURITY
(get/set)
DESCRIPTION
enable <boolean> 6/6 Enable or disable ipfilter settings
admin_enable <boolean> 6/6 Enable or disable the function always allow the
admin IP address to access this device
admin_ip 1.0.0.0 ~
255.255.255.255
6/6 Always allow this IP connect to camera when
admin_enable=1
maxconnection 0~10 6/6 Maximum number of concurrent streaming
connection(s) limit
allow_i<0~9>_start 1.0.0.0 ~
255.255.255.255
6/6 Allowed starting IP address for RTSP connection
allow_i<0~9>_end 1.0.0.0 ~
255.255.255.255
6/6 Allowed ending IP address for RTSP connection
deny_i<0~9>_start 1.0.0.0 ~
255.255.255.255
6/6 Denied starting IP address for RTSP connection
deny_i<0~9>_end 1.0.0.0 ~
255.255.255.255
6/6 Denied ending IP address for RTSP connection
ipv6_allow_i<0~9>
_start
1.0.0.0 ~
255.255.255.255
6/6 Allowed starting ipv6 IP address for RTSP
connection
ipv6_allow_i<0~9>
_end
1.0.0.0 ~
255.255.255.255
6/6 Allowed ending ipv6 IP address for RTSP
connection
ipv6_deny_i<0~9>_
start
1.0.0.0 ~
255.255.255.255
6/6 Denied starting ipv6 IP address for RTSP
connection
ipv6_deny_i<0~9>_
end
1.0.0.0 ~
255.255.255.255
6/6 Denied ending ipv6 IP address for RTSP
connection
Group: videoin
NAME VALUE SECURITY
(get/set)
DESCRIPTION
cmosfreq 50, 60 4/4 CMOS frequency
whitebalance auto, manual 4/4 auto, manual
atwbvalue 0 ~ 65535 4/4 The auto white balance value.
autoiris 0, 1 4/4 Enable auto Iris
enableblc 0, 1 4/4 Enable backlight compensation
agc normal,
max
4/4 Set auto gain control to normal level or MAX level
exposurelevel 1 ~ 8 4/4 Exposure level

Table of Contents