2-2 Vogt
®
VT Service Manual
Installation Instructions
FIGURE 2-1
Ice Machine Dimensions
Unit "A" "B" "C" "D" "E" "F"
VT40 72 5/8" 27" 24 3/8" 50 3/4" 44" 34"
VT60 89" 39 1/2" 30 1/2" 63 1/4" 57.5 68"
VT80 & VT100 44 7/8" N/A N/A
TABLE 2-1
Ice Machine Dimensions
Remote Weights Skid Mounted Weights
Model Lowside Condensing Unit Model Skid Mounted
VT40 520 lbs. 975 lbs. VT-40 1,525 lbs.
VT60 650 lbs. 1330 lbs. VT-60 2290 lbs.
VT80 1,475 lbs. 375 lbs. (condenser) VT-80 ----------
VT100 1,850 lbs. 400 lbs. (condenser) VT-100 ----------
TABLE 2-2
Weight Of Machines
Suction Hot Gas Liquid
Remote Condenser
Model Line Line Line
Discharge Liquid Return
VT40 1 3/8 OD 7/8 OD 5/8 OD N/A N/A
VT60 1 1/8 OD 7/8 OD
VT80 1 5/8 OD 1 1/8 OD 7/8 OD
VT100 1 3/8 OD
Note: Split systems will be supplied with Rota-lock adapters to connect the highside to the lowside
TABLE 2-3
Refrigerant Line Sizes
Machine Clearances:
A minimum three (3) feet of clearance is recommended around entire ice
machine. This will provide sufficient area for service and air flow.
Evaporator Installation:
Mount evaporator section (lowside) on storage area capable of sustaining its
weight and secure by thru bolting.
Note: Ambient at the lowside should remain between 50º
F
–105º
F. Makeup wa
ter temperature should
not drop below 40º
F. Machine may experience problems if operated outside of these ranges.