43
Resistance 2-lead measurement
Range Resolution Accuracy
400 Ω 0.1 Ω ±(1.0% + 4)
4 kΩ 0.001 kΩ
40 κΩ 0.01 kΩ±(1.5% + 2)
400 κΩ 0.1 kΩ
4 ΜΩ 0.001 MΩ ±(2.5% + 3)
40 MΩ 0.01 MΩ ±(3.5% + 5)
Overload protection 600 V
Resistance 4-lead measurement
Range Resolution Accuracy Test current
400 mΩ 0.1 mΩ ±(1.0% + 10) 200 mA
4 Ω 0.001 Ω
±(1.0% + 5)
20 mA
40 Ω 0.01 Ω 2 mA
Overload protection 30 V
Capacity
Range Resolution Accuracy
4 nF 0.001 nF not specified
40 nF 0.01 nF ±(5,0% + 20)
400 nF 0.1 nF
4 µF 0.001 µF ±(3,0% + 10)
40 µF 0.01 µF
400 µF 0.1 µF ±(4,0% + 10)
4 mF 0.001 mF ±(10,0% + 10)
40 mF 0.01 mF not specified
Overload protection 600 V
Diode Test
Test voltage Resolution Test current
2.8 V 0.001 V 1 mA (typical)
Overload protection 600 V
Acoustic continuity checker <35 Ω continuous sound, test current 1 mA typical,
overload protection 600 V
Do not exceed the maximum permitted input values. Do not touch circuits or parts of
circuits if there could be voltages higher than 25 V ACrms or 35 V DC present within
them! Risk of fatal injury!