EasyManua.ls Logo

Volvo Penta IPS800 - Page 49

Volvo Penta IPS800
132 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Settings
ACP has three function modes; these are set in the
Settings menu under ACP.
A Normal
means
that the system is active and working
in the optimal manner.
B Chlorine Free means that the system has switched
over to protection by the zinc anode for 4 h, resulting
in no chlorine gas being given off.
C Inactive this mode should only be used when the
boat is taken out of the water on to dry land.
To avoid fault codes, select inactive mode before
lifting the boat out of the water. In this mode the ACP
no longer monitors the corrosion condition, but the
IPS is protected by the zinc anode.
The system is re-started when the ignition is
switched on; inactive mode switches to Normal
mode.
Settings menu
1
Navigate to ACP in the settings menu. Press
to open the ACP menu.
2
Use to select desired setting.
Press to confirm the selection.
A
B
C
P0012971
Optional
47702095 04-2011 47

Related product manuals