EasyManuals Logo

Volvo Penta TAD1385VE User Manual

Volvo Penta TAD1385VE
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
EATS Inducements, GE-engines
AdBlue/DEF tank level
1 When the level in the tank falls to 15%, a yellow warning indicator is lit in combination with a solid NCD
symbol.
2 When the tank level reaches 6%, the warning indicator turns red and the NCD symbol starts to flash. After
7 minutes the engine is stopped.
3 If the engine is started when the tank level falls below 6%, the engine will only run at idle speed.
4 To revert the engine to full power, the tank level must be above 12%. To exit the inducement, the tank level
must be above 21%.
AdBlue/DEF, dosing and quality
A Engine rpm and torque
B Time axis
1 When a fault is detected, a yellow warning indicator is lit in combination with a solid NCD symbol.
2 If the fault is not resolved within 10 hours the warning indicator turns red and the NCD symbol starts to flash.
After 7 minutes the engine will be stopped.
3 If the engine has stopped it is possible to manually override the system actions and run the engine at full
power for 3 x 30 minutes. After 30 minutes the engine shuts down again. Each 30-minute period requires a
manual activation.
4 When the faults are remedied the engine will revert to full power.
Fault handling
47713625 06-2021 © AB VOLVO PENTA 47

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Volvo Penta TAD1385VE and is the answer not in the manual?

Volvo Penta TAD1385VE Specifications

General IconGeneral
Engine ModelTAD1385VE
Cooling SystemLiquid-cooled
Fuel SystemCommon rail
Displacement12.8 liters
AspirationTurbocharged
Emission ComplianceEU Stage V