100
4. Coolant temperature too low
CAUSE
Thermostat malfunction
REMEDY
Install a new thermostat
5. Engine does not reach correct speed
at wide open throttle (WOT)
CAUSE
Boat abnormally loaded
Fouling on underwater hull
Faulty/damaged propeller
Insufficient fuel flow
fuel filters clogged (due to contaminants/paraffin
precipitation in the fuel as a result of low outside
temperature)
Water in fuel
Insufficient air supply to engine
air cleaner filter clogged
air leak between turbo and engine’s inlet mani-
fold
dirt in turbocharger compressor
faulty turbocharger
poor engine compartment ventilation
Throttle controls incorrectly adjusted
Charge air cooler (CAC) clogged
TAMD71B: Faulty by-pass valve
High back pressure in exhaust system
Injector malfunction
TAMD73P and TAMD74: EDC system has tempo-
rarily reduced engine output due to alarm limit
being exceeded.
Faulty setting of injection pump
Fault in smoke limiter*
smoke limiter seizing
pressure pipe between inlet manifold and smoke
limiter leaking
faulty diaphragm in smoke limiter
faulty setting
* TAMD73P and TAMD74 engines are not equipped with a
smoke limiter.
REMEDY
If possible, reduce/redistribute the load
Clean the bottom of the boat and treat it with anti-
fouling paint
Replace the propeller
Fit new fuel filters (pre-filter and/or fine filters). Vent
the system as shown on page 54
Clean fuel tank. Drain water from pre-filter if installed
Fit new air cleaner filter(s)/clean air cleaner filter
Check the rubber hose between the turbo and the
connecting pipe, plus other connections. Tighten the
hose clips
Contact authorized service personnel
Contact authorized service personnel
Check that the ventilating ducts to the engine com-
partment are not blocked
Adjust the throttle controls
Clean the insert(s) as shown on pages 6062
Contact an authorized Volvo Penta service mechanic
Check that the exhaust pipe is not restricted in any
way
Get authorized service personnel to check the injec-
tors
Check any diagnostic trouble codes (DTC) set, see
page 102. Correct malfunction cause
Contact an authorized Volvo Penta service mechanic
Contact an authorized Volvo Penta service mechanic
Fit a new pressure line
Contact an authorized Volvo Penta service mechanic
Contact an authorized Volvo Penta service mechanic
7740156 - Downloaded from www.volvopenta.com 22/07/2009 00:44:08