Accelerator pedal position
Start position: 3.1
Length: 2 bits
Factor: 0.097752
(100/1023)%/bit
Offset: 0
0x0000-0x03FF = 0-100%
0x0400-0xFDFF = Not valid range
0xFE00-0x0FFE = Error indication
0xFFFF = Not available
Disable fuel
Start position: 5.1
Length: 2 bits
Factor: 1
Offset: 0
0 = Inactive
1 = Active
2 = Error indication
3 = Not available
NOTICE! Only used on dual speed Genset
Communication, J1939 Backbone 1 (BB1) - EMS
26 47706587 05-2015 © AB VOLVO PENTA