VWR 5000 Standard - User Manual

Default Icon
146 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Revision 11
15/05/17
Instruction Manual
Standard and Advanced
Orbital Shakers
Orbital Shakers Euro Plug UK Plug Swiss Plug
3500 Standard Orbital Shakers 444-2903 444-2904 444-2905
3500 Advanced Orbital Shakers 444-2906 444-2907 444-2908
3750 Advanced Reciprocating Shakers 444-2909 444-2910 444-2911
5000 Standard Orbital Shakers 444-2912 444-2913 444-2914
5000 Advanced Orbital Shakers 444-2915 444-2916 444-2917
10000-1 Advanced Orbital Shakers 444-2918 444-2919 444-2920
10000-2 Advanced Orbital Shakers 444-2921 444-2922 444-2923
15000-1 Advanced Orbital Shakers 444-2924 444-2925 444-2926
15000-2 Advanced Orbital Shakers 444-2927 444-2928 444-2929
European Catalogue Numbers:
EN - English ......... 1
FR - Français ......... 18
ES - Español ......... 36
IT - Italiano ......... 54
DE - Deutsch ......... 72
PT - Português ......... 90
NL - Nederlands ......... 108
NO - Norsk ......... 113
DA - Dansk ......... 118
SV - Svenska ......... 123
FI - Suomi ......... 128
HU - Magyar ......... 133
PL - Polski ......... 138

Table of Contents

Questions and Answers

  • M
    michelle82Aug 9, 2025
    What to do if my VWR 5000 Standard shows error E4?
    • M
      Miss Jessica HansonAug 9, 2025
      If your VWR Laboratory Equipment displays error E4, it indicates an issue with the load. Make sure the load is evenly distributed and does not exceed the unit's maximum load capacity.
  • C
    Calvin RamirezAug 15, 2025
    What to do if my VWR 5000 Standard Laboratory Equipment shows error E3?
    • R
      Rachael GonzalezAug 15, 2025
      If your VWR Laboratory Equipment displays error E3, first remove any mechanical obstructions. If the problem continues, it may be due to a drive system failure, ceased bearing or broken drive belt.
  • L
    linjohnAug 21, 2025
    Why my VWR Laboratory Equipment is excessively noisy?
    • A
      Andre SmithAug 21, 2025
      Excessive noise from your VWR Laboratory Equipment could be due to a misaligned sensor fan or motor. Check that the tray is tightly secured.
  • M
    Mr. Robert McguireAug 27, 2025
    How to fix VWR 5000 Standard that will not run?
    • J
      John CarpenterAug 27, 2025
      If your VWR Laboratory Equipment won't run, it might be due to a mechanical or motor obstruction. Add or replace the fuse as necessary.
  • J
    James StewartSep 2, 2025
    What to do if my VWR 5000 Standard shows error E7?
    • J
      John PriceSep 2, 2025
      If your VWR Laboratory Equipment shows error E7, try reducing the speed setting or the weight on the unit.

Summary

PACKAGE CONTENTS

WARRANTY

INSTALLATION

MAINTENANCE & SERVICING

INTENDED USE

EQUIPMENT DISPOSAL

ENVIRONMENTAL CONDITIONS

SAFETY INSTRUCTIONS

STANDARDS & REGULATIONS

OPERATING INSTRUCTIONS - STANDARD ORBITAL SHAKER

OPERATING TIPS

Advice for optimal performance, stability, and safety features.

CONTROL PANEL - ADVANCED ORBITAL SHAKER

OPERATING INSTRUCTIONS - ADVANCED ORBITAL SHAKER

LOAD SENSING FUNCTION

ADDITIONAL LOAD SENSING FEATURE

BEEPER PREFERENCE

Instructions on how to silence or restore audible beeper operation.

CALIBRATION PROCEDURE

Steps for self-calibrating the advanced orbital shaker.

RS-232 SERIAL PORT

Information regarding the serial port for data logging and control.

TECHNICAL SERVICE

TROUBLESHOOTING

ACCESSORIES

MICROPLATE CLAMP

VWR 5000 Standard Specifications

General IconGeneral
Capacity5000 g
Readability0.1 g
CalibrationExternal
Unitsg, kg, oz, lb
TimerYes