NOTE: There is 3 min of time delay protection for the compressor.
NOTE: the heat pump can run only if the water circle/filtration system is running.
5.4 Switch Heating & Cooling mode
Under main interface, press to switch Heating & Cooling mode.
5.5 Set the desired water temperature
When machine is under main interface in Heating or Cooling mode, press or directly to adjust
the desired water temperature, the data will be saved in 3 seconds or you can press to save the data.
5.6 Real data checking
Hold for 3 seconds to enter the real running data checking.
Press and to check below parameters , press to check the data of selected parameter,
press again to return back. Press to return back the main interface.
Parameter
Name
Range
A01
Inlet water temp.
-30~99
A02
Outlet water temp.
-30~99
A03
Ambient temp.
-30~99
A04
Exhaust temp.
0~125
A06
Piping system temp.
-30~99
A10
Compressor current
A11
Radiator temp.
A12
DC bus voltage
A13
Compressor speed
A14
PCB current
A15
DC fan motor speed
0~1590
NOTE: The other parameters which is not shown on below sheet is for reservation, no real function.