5.6 Low Oil Shutoff Switch (if equipped)
The low oil shutoff switch is designed to prevent engine damage
caused by an insufficient amount of oil.
When starting the machine:
if the warning light flashes quickly once, this indicates the engine
oil level is acceptable.
if the warning light flashes slowly, the engine will start but shut off
after 10-12 seconds, this indicates that the engine oil level is low.
Add oil to the engine. See Technical Data for oil quantity and
type.
if the warning light stays on continuously, the engine will start and
continue to run but the low oil shutoff switch is not functioning
properly. Check the switch for proper wire connections. If the light
continues to stay on, replace the switch.
if the warning light does not flash quickly once, and the engine
starts and continues to run, the low oil shutoff switch is not
functioning properly. Check the switch for proper wire
connections and grounding. If the light still does not flash when
starting the machine, replace the switch.

Other manuals for Wacker Neuson BS 60-4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson BS 60-4 and is the answer not in the manual?

Wacker Neuson BS 60-4 Specifications

General IconGeneral
Engine ManufacturerHonda
Displacement163 cm³
Operating Weight66 kg
Percussion Rate700 blows/min
EngineHonda GX 160
Stroke60 mm
Engine Type4-stroke
Fuel Tank Capacity3.0 liters

Related product manuals