Faults
T00998GB.fm 42
6.5 The charge control lamp will not extinguish
6.6 Engine does not start
Cause Remedy
Dynamo defective. Contact Wacker Neuson service dept.
Control unit defective.
Replace control unit (on rear of the
dynamo).
Cause Remedy
Ignition lock defective.
Change defective parts.Starter defective.
Start knop defective.
Battery flat. Charge battery.
Lack of lubricating oil.
Fill up with oil and actuate valve lever
at oil filter housing once.