EH 23, 27 Technical data
43
Extension cable for the US market:
Example
You utilize an EH 23/115
and want to use an extension cable with a length of
36 m (118 ft).
The machine has an input voltage of 115 V.
According to the table, the extension cable must feature a cross-section area of
4mm
2
(AWG 10).
Voltage
[V]
Extension
[ft]
Cross-section
area of cable
[AWG]
100 1~ < 79 14
< 125 12
< 197 10
115 1~ < 98 12
< 154 10
230 1~ < 157 16
< 253 14
< 397 12
< 492 10
120 1~ < 95 14
< 148 12
< 236 10
127 1~ < 112 14
< 174 12
< 276 10