EasyManuals Logo

Wacker Neuson GP 3800A User Manual

Wacker Neuson GP 3800A
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #36 background imageLoading...
Page #36 background image
Maintenance GP 3800A
36 wc_tx000793gb.fm
4.3 Engine Oil
4.3.1 Drain the oil while the engine is still warm.
4.3.2 Remove the oil filler plug (a) and the drain plug (b) to drain the oil.
Note: In the interests of environmental protection, place a plastic sheet
and a container under the machine to collect any liquid that drains off.
Dispose of this liquid in accordance with environmental protection
legislation.
4.3.3 Install the drain plug.
4.3.4 Fill the engine crankcase with the recommended oil up to the level of
the plug opening (c). See section Technical Data for oil quantity and
type.
4.3.5 Install the oil filler plug.
WARNING
Most used oil contains small amounts of materials that can cause cancer and other
health problems if inhaled, ingested, or left in contact with skin for prolonged
periods of time.
f Take steps to avoid inhaling or ingesting used engine oil.
f Wash skin thoroughly after exposure to used engine oil.
wc_gr000022

Table of Contents

Other manuals for Wacker Neuson GP 3800A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson GP 3800A and is the answer not in the manual?

Wacker Neuson GP 3800A Specifications

General IconGeneral
BrandWacker Neuson
ModelGP 3800A
CategoryPortable Generator
LanguageEnglish

Related product manuals