4.16 Setting the Gas Selector Valve (G models)
Overview
Your machine is configured at the factory to operate on natural gas. The gas
selector valve on the gas train allows you to convert the machine from natural gas
to LP as job site conditions require.
Procedure
To change the type of gas, follow the procedure below.
1. Ensure that the gas shutoff valve is closed.
2. Remove the gas type label (a) from the handle on the gas selector valve (b).
3. Loosen the screw (c) beneath the label.
4. Turn the handle to the desired position.
5. Tighten the screw.
6. Apply a new gas type label to the handle (extra labels are provided with the
machine).
7. Open the gas shutoff valve.
ghi_gr007393
a
c
b