MP15 Maintenance
wpm_tx001873gb.fm 24
5.6 Exciter Lubrication
See Graphic: wpmgr006018
The bearings in the exciter assembly are splash lubricated and rotate
at very high speed. It is important to maintain the exciter oil at the
correct level and change it regularly.
Check oil level in exciter every 50 hours of operation.
To check oil level, place plate on a flat, level surface. Remove the drain
plug (a) with seal ring (b). Oil level should be at drain plug threads. Add
oil as required.
Change exciter oil every 300 hours of operation.
To drain oil, remove plug (a) from end of exciter and tilt plate up.
Note: In the interests of environmental protection, place a plastic sheet
and a container under the machine to collect any liquid which drains
off. Dispose of this liquid in accordance with environmental protection
legislation.
Place plate on a level surface and add oil through plug opening until oil
reaches the drain plug threads. See Technical Data.
NOTICE: DO NOT overfill. Too much oil in the exciter can reduce
performance and damage the drive belt.
5.7 Cleaning Plate
Clean plate after use to remove dirt, stones, and mud caught under the
engine console. If plate is being used in a dusty area, check engine
cylinder cooling fins for heavy dirt accumulation. Keep engine cylinder
fins clean to prevent engine from overheating.
wpmgr006018
a
b

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson MP15 and is the answer not in the manual?

Wacker Neuson MP15 Specifications

General IconGeneral
BrandWacker Neuson
ModelMP15
CategoryConstruction Equipment
LanguageEnglish

Related product manuals