Super Finish 7000
2 5
6
1
4
3
9
7
8
11
10
5
6
7
8
12
GB
Article no. basic unit 2305973 2306248
Voltage : 230 Volt ~,
50 Hz
400 Volt ~,
50 Hz
Fuses : 16 A time-lag 16 A
Unit connecting line : 6 m long,
3x1.5 mm²
6 m long,
5x1.5 mm²
Max. current consumption
hose heating : 13.5 A 5.8 A
Degree of protection : IP 44 IP 44
Acceptance capacity : 2.8 kW 3.1 kW
Max. operating pressure : 25 MPa
(250 bar)
25 MPa
(250 bar)
Max. volume ow : 7.2 l/min 7.2 l/min
Volume ow at 12 MPa
(120 bar) with water :
5.8 l/min 5.8 l/min
Max. temperature of the
coating material : 43 °C 43 °C
Max. viscosity : 15 000 mPas 15 000 mPas
Empty weight pump : 60 kg 60 kg
Hydraulic oil lling quantity: 1.5 litre 1.5 litre
Max. vibration at the spray
gun :
lower than
2.5 m/s²
lower than
2.5 m/s²
Max. sound pressure level:
82 dB (A)* 82 dB (A)*
*Place of measurement: 1 m distance from unit and 1.60 m
above oor, 12 Mpa (120 bar) operating pressure, reverberant
oor
4 STARTUP
4.1 UNIT WITH SUCTION SYSTEM
1. Unscrew the dust protective cap (Item 1).
2. Ensure that the sealing surfaces of the connections are
clean.
Ensure that the red inlet (2) is inserted in the coating ma-
terial inlet (5).
3. If using the suction system
Screw union nut (3) on suction system (4) to the coating
substance inlet (5) with the spanner provided (41mm) and
fasten nger-tight.
If using the upper container (accessories)
Screw container adapter (12) to coating substance inlet
(5) and fasten nger-tight. Place upper container (9) on
container adapter (12) and align. Place return hose (7) in
upper container.
4. Screw the union nut (6) at the return hose (7) to the con-
nection (8) (22mm).
4.2 HIGH PRESSURE HOSE AND SPRAY GUN
A special adapter is required for operation
with several guns (see accessories). Several
adapters can be connected together, so that
two additional guns can be used per adapter.
Multi-gun operation is not possible when
working with high viscosity coating materials.
1. Screw adapter for multiple-gun operation to hose con-
nection (if required).
2. Screw the high pressure hose (10) onto the hose connec-
tion or the adapter.
Unused connections on the adapter must be
sealed with the protective caps provided.
Only connect as many hoses as will be used.
All connected hoses are pressurised!
3. Screw the spray gun (11) onto the high pressure hose
4. Tighten all union nuts on high pressure hose so that no
coating material can escape.
5. Screw the tip holder with the selected tip onto the spray
gun, align tip and tighten union nut.
When unscrewing the high pressure hose,
hold rmly on the hose connection with a
22mm wrench.