Air sampling smoke detection system
Fire Detection
TITANUS
PRO·SENS
®
Technical Manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the WAGNER TITANUS PRO-SENS 2SL and is the answer not in the manual?

WAGNER TITANUS PRO-SENS 2SL Specifications

General IconGeneral
BrandWAGNER
ModelTITANUS PRO-SENS 2SL
CategorySmoke Alarm
LanguageEnglish

Summary

General Information

Safety Information

Information on safety symbols and warnings used in the manual.

Product Description

TITANUS PRO·SENS® Features

Details on system features like sensitivity, LOGIC·SENS, and airflow monitoring.

Areas of Application

Describes suitable applications for early smoke detection in various environments.

Technical Description

Pipe System

Details the components and design of the air sampling pipe system.

Technical Data

TITANUS PRO·SENS® Specifications

Technical specifications for the main device, including voltage, current, dimensions, and housing.

Design and Project Planning

Pipe System Design Guidelines

Guidelines for designing the pipe system, including symmetry and aperture rules.

Air Flow Monitoring and Sensitivity

Details on adjusting air flow sensitivity and monitoring parameters.

Project Planning Limits

Specifies limits for pipe length and aspiration apertures per project type.

Installation Procedures

Detector Module Settings

Configuration of detector module settings, including sensitivity and delay periods.

Pipe System Installation

Monitoring in Forced Air Flow Systems

Positioning sampling points in forced air flow systems for effective detection.

Detonation Prevention Device Installation

Installation of detonation prevention devices in explosive areas.

Commissioning Procedures

Air Flow Sensor Adjustment

Procedures for adjusting the air flow sensor for accurate readings, considering air pressure.

Detector Module and Alarm Transmission Check

Activating the detector module and checking alarm signal transmission to the CFDU.

Air Flow Monitoring Checks

Verifying the detection of pipe fractures and blockages via air flow monitoring.

Operational Check

Performing functional checks on the system using test equipment and procedures.

Maintenance Procedures

Detector Module Exchange

Step-by-step guide for replacing a detector module.

Air Flow Sensor Adjustment Check

Verifying the air flow sensor adjustment and its dependency on air pressure.