Do you have a question about the WAGNER TITANUS PRO-SENS and is the answer not in the manual?
Type | Aspirating Smoke Detector |
---|---|
Airflow monitoring | Yes |
Power Supply | 24 V DC |
Weight | Approx. 3.5 kg |
Standards | EN 54-20 |
Supply voltage | 24 V DC |
Relay outputs | 3 |
Humidity Range | 10% to 95% RH (non-condensing) |
Detection Principle | Optical detection |
Introduces the manual for installers and outlines its scope and liability.
Details safety precautions and symbols used in the manual to avoid damage.
Outlines the terms and conditions of the product guarantee and liability.
States the copyright ownership and restrictions on manual reproduction.
Describes the packaging materials and recommendations for handling.
Provides instructions for the proper disposal of packaging and components.
Details key features including sensitivity, LOGIC·SENS, and airflow monitoring.
Describes various environments and scenarios where the system is suitable for early smoke detection.
Explains the basic device, aspiration unit, detector module, and airflow sensor functionality.
Presents an overview of the device, its main components, and optional accessories.
Lists and illustrates the various components used in the air sampling pipe network.
Provides detailed technical specifications including voltage, current, dimensions, and environmental data.
Specifies technical data related to pipe system configurations like length and monitoring area.
Outlines general project planning criteria, guidelines, and relevant regulations.
Covers guidelines for designing the pipe system to ensure reliable fire detection.
Explains how to adjust and configure the air flow monitoring system and sensitivity.
Specifies limit values for pipe length, aspiration apertures, and planning types.
Provides guidelines for pipe system design and details accessory components.
Covers specific design aspects for individual aperture monitoring and specialized layouts.
Outlines general regulations and precautions to be taken during installation.
Details how to configure detector module settings like sensitivity and delay periods.
Explains the procedure for installing the optional reset board.
Discusses proper placement and methods for mounting the device securely.
Covers the general steps and safety precautions for making electrical connections.
Provides step-by-step instructions for adding a second detector module.
Covers general requirements and characteristics for pipe system components.
Discusses temperature effects on pipe length and management of linear expansion.
Details the installation of patented aspiration apertures with film sheets.
Explains the installation of ceiling feed-throughs for hidden pipe system routing.
Addresses system installation in ventilation or climatic applications.
Details the installation procedures for various types of air filters.
Describes the installation of detonation prevention devices in hazardous areas.
Details how to adjust the air flow sensor for correct operation.
Covers activating detector modules and verifying alarm signal transmission.
Explains how to verify the proper functioning of the air flow monitoring system.
Outlines the steps for performing a functional operational check of the system.
Details items to check during a routine visual inspection of the system.
Explains the meaning of LED flash codes for indicating faults and device status.
Provides step-by-step instructions for replacing a detector module.
Details the process for cleaning or changing the LF-AD-x air filter inserts.
Guides on checking and verifying the air flow sensor adjustment.
Outlines the recommended intervals and required checks for system maintenance.
Provides tables for air pressure-dependent adjustment of the air flow sensor.
Contains tables for project planning based on system configurations and accessories.
Lists product codes, descriptions, and units for system components.
Includes a protocol form for recording commissioning and maintenance data.
Provides definitions of technical terms used throughout the manual.