EasyManuals Logo

Walker MT User Manual

Walker MT
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #48 background imageLoading...
Page #48 background image
Maintenance Instructions
4
4
MAINTENANCE SCHEDULE CHART - RECOMMENDED SERVICE INTERVALS - MODEL MT
Service Item
Daily
25
Hours
100
Hours
200
Hours Yearly
Every
2Years
Ref.
Page
Check Engine Crankcase Oil Level x 46
Check/Clean Engine Air Cooling System* x 57
Check Security of Air Filtration Components x 60
Check Air Filter Restriction Gauge x 54
Clean Grass Buildup Under Deck x 58
Clean GHS Exhaust Screen* x 40
Clean GHS Blower* x 59
Service Mower Blades x 61
Check Functions of Instrument Panel and
Warning Horn
x22
Lubricate Grease Fittings and Oil Points* x 47
Check PTO Gearbox Oil Level** x 51
Check Battery Electrolyte Level x 60
Check Hydrostatic Transmission Fluid x 52
Check Tire Pressure x 61
Check Drive Belts (Jackshaft, Engine PTO,
GHS Blower, Ground Drive)
x62
Check Gearbox Oil Seals x 63
Check Turbine Precleaner* x 54
Check/Clean Primary Air Filter Element
x54
Change Engine Crankcase Oil
∆∆
x46
Check/Adjust Blade Clutch (PTO)/
Brake Action
x74
Check Oil Level in Gear Axle x 51
Clean Hydrostatic Transmission Cooling Fins x 60
Clean Engine Cooling Fins x 57
Check/Regap Spark Plugs x 63
Change Engine Oil Filter x 46
Check Fuel Lines and Clamps x 63
Check/Clean Secondary Air
Filter Element and Foam Precleaner
x56
Replace Primary Air Filter Element
and Vacuator™ Valve
x54
Replace Fuel Filter x69
Service Battery x60
Check/Adjust FSC Friction Lock x 79
Service Solenoid Shift Starter x 63
Change Gear Axle Oil
∆∆∆
x51
Change Hydrostatic Transmission Fluid
∆∆∆
x52
Replace Fuel Lines and Clamps x63
More often in extremely dusty or dirty conditions (refer to notes about air cleaner element in
IMPORTANT TIPS FOR CARE OF KOHLER ENGINE)
∗∗ Change PTO gearbox oil after first 100 hours of operation (break-in period)
Primary air cleaner is remote mounted Donaldson Radialseal™ unit, secondary air cleaner is
standard Kohler engine mounted unit, replace primary filter every year or after 6 cleanings
∆∆ Change engine oil and filter after first 5 hours of operation of a new engine (break-in period)
∆∆∆ Change every 2 years or 1000 hours
CAUTION
Maintenance procedures requiring special training or
tools should be performed by a trained technician.

Table of Contents

Other manuals for Walker MT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Walker MT and is the answer not in the manual?

Walker MT Specifications

General IconGeneral
CategoryLawn Mower
ManufacturerWalker
ModelMT
Fuel TypeGasoline
Transmission TypeHydrostatic
Deck MaterialSteel
EngineKohler Command Pro