Primary Charger
Configuration
Number of Chargers:
Input the number of chargers including
the Primary charger
Maximum current per phase:
It is the maximum current that can be
supplied to the charging network. This
value is usually the rated current of the
MCB
Minimum current per charger:
From 6 A to 10 A. The default value
is 6 A
Mains Breaker Maximum current:
The maximum current that can
be supplied to the electrical installation.
This value is the rated current of the
mains circuit breaker that protects the
electrical installation.