EasyManua.ls Logo

WAMGROUP MBF 042 - Noise Level; Environmental Operating Limits

Default Icon
187 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3.6 Noise level
VL
3.0 TECHNICAL INFORMATION
2
VAL.130.--.M.EN Issue: A1
09.16
13
The noise level of the VIB valve operating on empty does not exceed 50 dB(A), the value measured at a dis-
tance of 1m, in the most unfavourable position.
This may vary according to the type of material handled and the type of actuator applied.
Danger - Warning
Depending on the installation site, the installer must adopt suitable systems (barriers, etc.), if neces-
sary, to maintain the noise levels within the legally permitted limits.
3.7 Environmental operating limits
8QOHVVRWKHUZLVHVSHFL¿HGWKHYDOYHFRQFHUQHGPD\EHXVHGRQO\ZLWKLQWKHOLPLWVLQGLFDWHG
- Altitude: less than 1,000 m at sea level
- Environmental temperature: between - 20 °C and + 40 °C
Maximum temperature of dusts: +80 °C continuous, +90 °C for short time intervals (maximum of 1 minute).
7KHVHWHPSHUDWXUHOLPLWVDUHOLQNHGWRWKHIHDWXUHVRIWKHJDVNHWVDQGSODVWLFFRDWLQJVLIWKHLUHI¿FLHQF\LV
affected by extremely high temperatures, it leads to loss of material and formation of potentially explosive
hazardous mixtures.
- Cold climates: with temperature less than 5 °C use oil and lubricants suitable to the operating temperature.
It is forbidden using the seal adjustment in the absence of wear or leakage problems.
It is forbidden washing / cleaning the valve using high pressure devices.
It is forbidden to use the slide valve for hot materials with temperatures exceeding 60°C and cold materials
with temperatures below - 20°C.
It is forbidden to disassemble the valve or its components if material is present upstream the valve.
It is forbidden using the hammer on the aluminium valve body.
VIB - type Slide Valves are dust proof but they are NOT pressure proof.
NOTE: Depending on the type of plant, the valve can be operated either manually, electropneumatically or by
a gear motor. In the two latter versions the valve is controlled by a remote control panel or by a local
starter.
The weight of the material column must not exceed the resistance of the mobile valve parts.
Materials with bulk density < 1.3 t/m³ normally do not create any problem. When dealing with materials with
higher bulk density check with WAMGROUP customer service.

Table of Contents