EasyManua.ls Logo

WarmFlow Utility Combi UC70HEE User Manual

Default Icon
107 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Boiler Manual
Incorporating: User Instructions
Installation Instructions
Service Instructions
Guarantee Terms & Conditions
High Efficiency
Condensing Boilers
For use with Kerosene only
Models covered by this manual:
B-Series
Boilerhouse B70HE B90HE B120HE
U-Series
Utility U70HE U90HE U120HE U150HE
Utility Pumped UP70HE UP90HE UP120HE UP150HE
Utility System US70HE US90HE US120HE
Utility Combi UC70HEE UC90HEE UC120HEE
K-Series
Kabin Pak K70HE K90HE K120HE K150HE
Kabin Pak Pumped KP70HE KP90HE KP120HE KP150HE
Kabin Pak System KS70HE KS90HE KS120HE
Kabin Pak Combi KC70HEE KC90HEE KC120HEE
Utility Combi and Kabin Pak Combi models Patent Pending UK Application No. GB1613466.0
LEAVE THIS MANUAL WITH THE END USER

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the WarmFlow Utility Combi UC70HEE and is the answer not in the manual?

WarmFlow Utility Combi UC70HEE Specifications

General IconGeneral
BrandWarmFlow
ModelUtility Combi UC70HEE
CategoryBoiler
LanguageEnglish

Summary

User Instructions

Dual Thermostat Operation

Explains radiator temperature control via boiler and high limit thermostats.

High Limit Thermostat Reset Procedure

Details how to reset the high limit thermostat after it has tripped.

Burner Lockout Fault Diagnosis

Describes burner lockout conditions, causes, and the reset procedure.

Condensing Boiler Installation Requirements

Combi Boiler Pre-Installation Checks

Combi Boiler Operation Details

Heat Exchanger Baffle Positioning

Technical Details Overview

Combi Sequence of Operation Flow Chart

Visualizes the operational sequence for Combi boilers.

Condensate Disposal System

Technical Data Tables

B-Series Boilerhouse Technical Data

Presents technical specifications for B-Series Boilerhouse models.

U-Series Utility Pre-Wired (UHE) Technical Data

Details technical specifications for U-Series Utility Pre-Wired (UHE) models.

U-Series Utility Pumped (UPHE) Technical Data

Lists technical specifications for U-Series Utility Pumped (UPHE) models.

U-Series Utility System (USHE) Technical Data

Provides technical specifications for U-Series Utility System (USHE) models.

U-Series Utility Combi (UCHE) Technical Data

Details technical specifications for U-Series Utility Combi (UCHE) models.

K-Series Kabin Pak Pre-Wired (KHE) Technical Data

Presents technical specifications for K-Series Kabin Pak Pre-Wired (KHE) models.

K-Series Kabin Pak Pumped (KPHE) Technical Data

Lists technical specifications for K-Series Kabin Pak Pumped (KPHE) models.

K-Series Kabin Pak System (KSHE) Technical Data

Provides technical specifications for K-Series Kabin Pak System (KSHE) models.

K-Series Kabin Pak Combi (KCHE) Technical Data

Details technical specifications for K-Series Kabin Pak Combi (KCHE) models.

Electricity Supply and Wiring Details

Dual-Safe Thermostat for Non-Combi Boilers

Describes the Dual-Safe Thermostat for non-Combi boilers.

RDB Burner Control Box Wiring

Illustrates the RDB Burner Control Box wiring.

Combi Boiler Wiring Diagrams

Combi Wiring Diagram

Shows the wiring diagram for Combi models.

Combi Wiring Schematic

Presents a wiring schematic for Combi models.

Oil Supply System Types

Flue System Information

Condensing Boiler Flue Kits

Information on flue kits for condensing boilers and fire safety.

Fit Flue Thermostat for Condensing Kits

Instructions for fitting the flue thermostat.

Connect Thermostat Wiring for Condensing Kits

Steps to connect the flue thermostat wiring.

FBF Kit Flue Terminal Measurement and Cutting

Instructions for measuring and cutting the flue terminal.

FBF Kit Terminal and Air Hose Connection

Steps for connecting the terminal and air hose.

FBF Kit Flue Thermostat Fitting

Instructions for fitting the flue thermostat before kit installation.

FBF Kit Starter Piece Installation

Steps for fitting the starter piece of the flue kit.

HBF Kit Flue Terminal Measurement and Cutting

Instructions for measuring and cutting the flue terminal.

VBF Kit Flue Thermostat Fitting

Instructions for fitting the flue thermostat before kit installation.

VBF Kit Starter Piece Installation

Steps for fitting the starter piece of the flue kit.

VBF Kit Extension and Air Hose Connection

Steps for connecting the first extension and air hose.

VBF Kit Terminal Measurement and Cutting

Instructions for measuring and cutting the flue terminal.

Flue Length Calculation Guide

Provides a method for calculating equivalent flue length.

Plume Kit Terminal End Removal

Steps to remove the terminal end of the flue.

Plume Kit Excess Material Cutting

Instructions for cutting excess flue material.

Plume Kit Diverter Elbow Fitting

Steps for fitting the diverter elbow.

Plume Kit Assembly Instructions

Instructions for assembling the plume management kit.

Air Supply for Combustion and Ventilation

Installation Requirements Overview

General Installation Requirements

Covers requirements for hearth, service access, heating system, and pipework.

Sealed System Installation Details

Combi Domestic Hot Water Installation

Boiler Burner Components and Operation

RDB Burner Component Identification

Identifies components of the RDB Burner.

Commissioning and Servicing Procedures

Boiler Commissioning Requirements

Procedures and requirements for boiler commissioning.

Boiler Servicing Requirements

General requirements for annual boiler servicing.

Burner Fault Finding Guide

Riello RDB Burner Fault Finding Chart

A flowchart for troubleshooting Riello RDB burner faults.

Combi Boiler Fault Finding

Central Heating Fault Finding

Troubleshooting flowchart for Combi central heating issues.

Domestic Hot Water Fault Finding

Troubleshooting flowchart for Combi domestic hot water issues.

Guarantees, Terms, and Conditions

Warmflow Guarantee Terms

Details the terms and conditions of Warmflow guarantees.

Conditions for Guarantee Validity

Outlines the conditions that must be met for the guarantee to be valid.

Related product manuals