Page #1 background image
Power O F F Power O N (Air) Power O N (F loor)
Dual Touch Programmable Thermostat - User Guide
Models - W3115DT / W3115DT AU / W3115DT Black
1 Description
1.1 The Dual touch programmable thermostat has three
temperature control modes:
A mode:
F mode:
AF mode:
controls the ambient air temperature
controls the floor temperature using an
external  sensor
controls the ambient air temperature
maintains the floor temperature within
desired limits using an external
temperature sensor
Time
Day
Mode
A/ F / AF mode
Period display
Power button
Menu button
Check button
Setting function
Temperature
Return button
Preset temperature
Adjustment buttons
Power off the thermostat when not in use (eg summer).
This will not affect the time and temperature settings.
After Power-on, the  shows the Power O F F
display (see image 1)
Press the Power button for the Standby screen
(image 5)
Press the Power button again for the Power O N screen.
Press the Power button for 3 seconds for the Power
O F F screen (this will stop the scheduling and the towel
rail mode).
1
2
3
4
5
1.2 Preset Temperatures
The thermostat has 3 modes of temperature operation:
Comfort temperature
E conomy temperature
Vacation temperature
The following table shows the intended use and the
default setting of each of the preset temperatures.
Mode A/ AF mode F mode Towel Rail
Comfort (when at home) 21° C 24 ° C
E conomy (when asleep 17 ° C 16 ° C
or away from home
Vacation (during a 10° C 10° C
prolonged absence)
As per heated
towel rail
specifications
Modes of Operation
2
2.1 Automatic mode
The thermostat has 4 modes of operation:
- U se the scheduling time to control
temperature.
Programmed Schedule
The schedule consists of 4 periods per day, which
represents a typical week day. Y ou can program the
thermostat to skip the periods that do not apply to your
situation. F or example, you can skip periods 2 and 3 for
the weekend.
Period Temperature MO N TU E W E D THU F RI SAT SU N
2.2 Manual Mode
- The temperature must be set manually.
Y ou can modify the preset temperature by pressing

  when the thermostat is in automatic
mode. The new temperature will be used until the
beginning of the next period.
2.3
- The thermstat uses the vacation
preset temperature to control this mode.
Vacation Mode
2.4
- The following table shows the
intended use and the default setting of each of the preset
times.
Towel Rail Heating Mode
Power O N (Air+ F loor) Standby
5:3 0 5:3 0 5:3 0 5:3 0 5:3 0 6 :00 6 :00
8 :00 8 :00 8 :00 8 :00 8 :00 9 :00 9 :00
18 :00 18 :00 18 :00 18 :00 18 :00 18 :00 18 :00
21.3 0 21.3 0 21:3 0 21:3 0 21:3 0 21:3 0 21:3 0
Period Temperature MO N TU E W E D THU F RI SAT SU N
As per heated
towel rail
specifications
5:3 0 5:3 0 5:3 0 5:3 0 5:3 0 6 :00 6 :00
8 :00 8 :00 8 :00 8 :00 8 :00 9 :00 9 :00
18 :00 18 :00 18 :00 18 :00 18 :00 18 :00 18 :00
21.3 0 21.3 0 21:3 0 21:3 0 21:3 0 21:3 0 21:3 0
Comfort
Economy
Comfort
Economy
F F
Floor set temperature Air+Floor set temperature
MON
C
C
Set
Floor
MON
C
C
Set
Air
Air set temperature
MON
C
C
Set
Air
Question and Answer IconNeed help?

Do you have a question about the Warmup W3115DT AU and is the answer not in the manual?

Warmup W3115DT AU Specifications

General IconGeneral
TypeProgrammable Thermostat
Temperature Range5°C to 35°C
Control MethodTouchscreen
Wi-Fi ConnectivityYes
CompatibilityElectric Underfloor Heating
DisplayLCD

Summary

Product Description

Temperature Control Modes

Details on A, F, and AF modes for controlling ambient and floor temperatures.

Preset Temperatures Overview

Explains Comfort, Economy, and Vacation temperature modes and their default settings.

Thermostat Modes of Operation

Automatic Mode with Scheduling

Utilizes programmed schedules for temperature control throughout the week.

Manual Mode Operation

Allows manual adjustment of temperature, effective until the next scheduled period.

Vacation Mode

Uses a specific vacation preset temperature for extended absences.

Towel Rail Heating Mode

Details the intended use and default settings for towel rail heating periods.

User Setting Operations

Date and Time Configuration

Guide for setting the current date, year, month, day, hour, and minute.

Mode and Schedule Setup

Instructions for selecting operation modes and configuring daily schedules.

Towel Rail and Screen Settings

Procedures for setting towel rail periods and cleaning the screen.

Brightness Adjustment

How to adjust the display brightness level.

Troubleshooting and Specifications

Error Message Interpretation

Explanation of error codes (LO1, HI, LO2, HI2) related to temperature readings.

Technical Specifications

Details on power supply, load, display ranges, and operating conditions.

Warranty and Support

Information on the 3-year warranty, exclusions, and customer assistance contacts.