Do you have a question about the Warmup 3IE and is the answer not in the manual?
Display Type | LCD |
---|---|
Compatibility | Electric underfloor heating systems |
Energy Monitoring | Yes |
Power Supply | Mains |
Maximum Load | 16A |
Air Sensor | Yes |
Wi-Fi Connectivity | No |
Programming | 7-day programmable |
Supply Voltage | 230V AC |
Temperature Range | 5°C to 40°C |
Floor Sensor | Included |
Approvals | CE |
Dimensions | 86mm x 86mm |
Display | Full color touchscreen |
Explains basic button functions and screen interactions for using the thermostat.
Details how the thermostat enters and exits standby mode.
Explains how to turn the thermostat and heating system on/off.
Explains the GFCI feature for detecting current leakage and safety.
Lists scenarios indicating GFCI faults and required customer service contact.
Advises that the GFCI test should be performed monthly.
Explains that the thermostat guides users through an initial setup procedure upon power-up.
Lists the various configuration options available during initial thermostat setup.
Instructs users on how to access the main menu for programming and settings.
Details options for setting programs daily, by weekday/weekend, or all days the same.
Explains how to set a single, constant temperature for the thermostat.
Refers to selecting pre-set programs as explained in a table.
Describes how to adjust the target floor temperature using up/down buttons.
Explains how to add additional time periods to a daily program.
Explains the summary page showing the set program and options to edit or copy.
Recommends setting a low target temperature overnight to save energy.
Describes how to set the target temperature to "OFF" to disable heating.
Details the process of confirming the program and returning to the home screen.
Introduces pre-set schedules for different rooms to simplify programming.
Explains how to access the "view / edit program" option from the menu.
Details how to select a specific day to view or edit its heating schedule.
Describes how to enter "edit" mode to change heating periods for a selected day.
Explains how to view the schedule for the next day after selecting a day.
Explains holiday mode allows overriding schedule with a fixed temperature for energy saving.
Details how to set the start and end dates for the holiday mode period.
Describes how to set the fixed temperature to be maintained during holiday mode.
Explains how to cancel the holiday mode at any time by pressing "cancel".
Explains how to view energy usage and set parameters for cost estimation.
Guides users to select "view energy use" to check energy consumption over a period.
Explains that "load settings" requires entering the total power of the heating system.
Suggests altering heating programs and comparing usage to identify energy savings.
Explains how to interpret the energy usage graph, with red bars representing time periods.
Details setting cost parameters in "energy settings" for accurate cost estimation.
Explains single energy tariff versus standard/low energy tariff structures.
Guides users on setting the cost per Kilowatt hour (KWH) for energy tariff calculations.
Details setting times and costs for standard/low energy tariffs, including period display.
States the thermostat is flexible and configurable to meet user requirements.
Covers setting time, date, time format, and automatic daylight savings.
Explains how to select the preferred language for the thermostat's operations.
Allows selection of temperature units (°C or °F) for display and regulation.
Covers theme, brightness, heating LED, audio feedback, and child lock settings.
Explains selecting floor or air temperature sensors for thermal regulation.
Allows changing the home and standby screen themes and brightness levels.
Sets the LCD screen brightness in standby mode from 0 (dimmest) to 5 (brightest).
Sets the LCD screen brightness during normal operation from 1 (dimmest) to 6 (brightest).
Allows turning off the heating indication LED, which signals heating start/stop.
Allows disabling the beep sound that occurs when a button is pressed.
Describes child lock creating a delay to exit standby mode, requiring a long press.
Explains thermostat's capability to use floor, air, or both sensors for thermal regulation.
Uses floor sensor readings to determine if heating is required to meet the target temperature.
Uses floor sensor, but suspends heating if air temp exceeds a set limit.
Uses air sensor readings (inside thermostat) to determine if heating is required.
Advises re-programming the thermostat after changing heating target settings.
Warns that advanced settings affect performance and require installer or support.
Details programmable limits (min/max air/floor temps) for various floor coverings.
Specifies the overheat limit settings for different floor types to prevent damage.
Allows users to define custom limits for air, floor, and overheat settings.
Explains how floor type setting affects programmable temperature limits and overheat limits.
Guides on setting up one thermostat to control another for multiple heating elements.
Provides step-by-step instructions for connecting and configuring master/relay thermostats.
Clarifies that the relay thermostat does not require its own floor sensor.
Describes attaching and defining the use of a second sensor for external readings.
Explains how external sensor data enables weather compensation for energy savings.
Used for large or delicate floor areas to monitor the overheat limit with a secondary sensor.
Lists compatible probe types (NTC 10K, 12K, 15K) for thermostat functionality.
Allows adjusting sensor temperature readings up or down to improve accuracy.
Describes how to perform a system reset to restore factory default software settings.
Covers Warmup Inc's 3-year warranty against defects in workmanship or materials.
Outlines procedures for returning defective products or contacting Warmup for resolution.
Specifies that warranty does not cover reinstallation costs or damage caused by the consumer.
States Warmup is not liable for incidental or consequential damages beyond repair/replacement.
Encourages users to register their Warmup product online for support.