Ensure no foreign particles enter pump outlets to prevent malfunction and damage.
Do not connect the pump directly to water mains pressure; it may cause damage.
Choose an accessible position, consider potential leaks, and ensure ventilation.
Keep solder flux away from plastic parts, especially push fit retaining rings.
Purge pump with water for 5 mins before running; check for leaks.
Do not use any jointing compounds for hot water cylinder connections.
Do not connect the cold water supply directly to the water mains.
Do not use any jointing compounds for cold water supply connections.
Do not use any jointing compounds when connecting the pump.
The pump must be earthed to prevent electrical hazards.
Connect to a 230V 50Hz supply with a 5A switched spur and double pole disconnection.
Connect Brown to L (Live), Yellow/Green to E (Earth), Blue to N (Neutral).
It is recommended to install a residual current device (RCD) for added safety.
Thoroughly purge the system with water before switching on the electrical supply.
Check electricity, fuses, valves, filter blockages, orientation, and water flow.
Check hot water outlet flow back, stopped flow, trapped air, or jammed flow switch.
Phone the helpline for assistance with product malfunction before making a claim.
Do not remove the pump from installation; doing so will invalidate the guarantee.