1. Regeneration Time ( r ) Example [ r 2A ]
- The time of day at which regeneration may take place is designated by the letter “r”.
- Default regeneration time setting for SOFTENERS is 2a
- The rst display digit indicates A.M. or P.M. To change the value, press the Set/Change button.
- Press Menu/Enter button to accept the value and move to the next digit.
- The second and third display digits indicate the hour at which the regeneration will occur.
- Change the digits with the Set/Change button and accept with the Menu/Enter button.
- After the entire display ashes, press the Menu/Enter button to move to the next menu item.
2. Regeneration Day Override (A) – Meter (Demand) Mode Only
- Press Menu/Enter button. This display is used to set the maximum amount of time (in days)
the unit can be in service without regeneration. This setting is identied by the
letter “A” in the left digit. Regeneration will begin at the scheduled time. A setting of zero
will cancel this feature.
- Example: Override every 7 days (A-07), default setting, or cancel setting (A-00). Maximum is 29.
3. Regeneration Cycle Step Times (Steps 1, 2, 3, 4)
Example [ 3 - 10 ]
- The next 4 displays set the duration of time in minutes for each regeneration cycle step. The step
number which is currently modiable is indicated on the far left of the display screen.
- The number of minutes allotted for the selected backwash step is displayed on the far right.
- Change the digit values using the Set/Change and Menu/Enter buttons as described above.
4. System Capacity in Grains ( c )
- Press the Menu/Enter button. This display is used to set the system capacity in grains and is used
in conjunction with the hardness setting to calculate total gallons of treated water available
between regenerations. This option is identied by the letter “c” in the left digit. The maximum
value for this item is 399.
Example: 32,000 grain capacity ( c 032 ).
5. Reserve Capacity Setting % Example (p - 25)
6. Bluetooth Enabled BE - 1 (ON)
BE - 0 (OFF)
7. Bluetooth Password BBPP is displayed for one second, then password is displayed.
8. To Exit the Master Programming Mode, press the Menu/Enter button until time of day returns.
Note: If no buttons are pressed for 60 seconds, the Master Programming Mode will be exited automatical
ly.