-Pre-Installation Check List-
A water test should always be performed in order to determine total water hardness (in gpg) and total
dissolved iron (in parts per million - ppm). This is critical for proper equipment selection, sizing and for
determining the program for regeneration frequency. If heavy concentrations of iron (above 5 ppm), iron
coloration, iron bacteria or sediment are present, ltration prior to the softener will most generally be re-
quired. Certain states may require a licensed plumber for installation.
Note: Flexible water supply connectors and exible drain line tubing may not be allowed in you locale.
Please check with local plumbing code ocials prior to installation.
Installation Requirements
• A level oor position ahead of piping into water heater.
• Unit must be installed at least 10’ ahead of the inlet to a water heater to prevent damage due to back-up
of hot water.
• DO NOT install the unit in an area of direct sunlight or where freezing temperatures may occur!
(See Installation Diagrams for proper placement and plumbing connections.)
-Major System Components-
1. Brine Tank - This tank holds the salt that is added to the softener. This salt is dissolved with water to form
a brine solution used in the softener regeneration process.
2. Resin Tank - This tank contains the ion exchange resin media. Water ows through the resin tank under
pressure to come into contact with the resin for water softening.
3. Control Valve - The valve directs water through the resin tank for water softening and controls the ow of
water / brine for the regeneration process.
Installation