10) Open the feed water valve and open the RO faucet until water ows freely from the spout. Close the RO
faucet. Hold the disinfectant solution in the RO system, including the tubing and faucet, for a minimum of
10 minutes. Open the tank ball valve.
11) Shut off the feed water valve and open the RO faucet. Let water run out until the ow stops at the RO
faucet.
12) Open the feed water valve. Let water ow freely from the faucet for three minutes. Shut off the water at the
source water supply with RO faucet open.
13) When the ow of water has stopped at the RO faucet, remove the lter housing sumps and membrane
housing from the RO system. Replace the lters and membrane according to the service life.
14) Replace the housings on the RO system. Open the source water valve and allow the water to ow from
the faucet.
• Becausesomeofthedisinfectantmaystillbeinthesystem,thesystemshouldbeushedpriorto
using the water human consumption.
A maintenance record should be kept for the RO system, including information about the
replacement parts, when service was performed, and by whom.
CLEANING PROCEDURES - CONTINUED