3.1.1 Manual mode Comfort
Manual working mode, the comfort setting temperature will
be followed all the time.
By pressing (-) or (+) keys, the comfort setting temperature
starts to blink and can be adjusted.
3.1.2 Manual mode, Reduced
Manual working mode, the reduced setting temperature will
be followed all the time.
By pressing (-) or (+) keys, the reduced setting temperature
starts to blink and can be adjusted.
3.1.3 OFF mode
Use this mode if you need to switch off your installation.
Be Careful: In this mode your installation can freeze.
- At any time, when display is off, press on the (Ok) key to
display a few seconds the current temperature and time.
- To exit the operating mode, use the navigation keys (◄)
or (►).
3.1.4 Anti-freeze mode
Use this mode if you want to protect your installation
against freezing. (During holidays…)
- The anti-freeze setting temperature is fixed and can be
adjusted in the parameter menu number
06 ‘HG’, see chapter 6. (Default value 10°C)
3.1.5 Timer mode
The Timer mode allows you to adjust, the temperature and
the duration for a special time.
This function can be used when you stay at home for
several days, or if you want to override the program for
some time (reception...)