12
Fault
code
Description Possible cause Correction
Display
A02
Compressor
1 shut-down
due to high
pressure
Pressure switch
defective or power
circuit interruption/
short circuit or
wrong high pres-
sure sensor reading.
Please contact your au-
thorised Webasto Marine
dealer.
COOLING MODE:
insucient sea
water cooling. Sea
water strainer soiled
or no intake.
Remove blockage at sea
water inlet. The minimum
flow rates must be com-
plied with. Clean sea water
strainer and bleed sea
water circuit.
HEATING MODE:
Cold water flow
rate too low.
Check operation of the
cold water pump. If fitted,
open shut-off cock valves.
Please contact your au-
thorised Webasto Marine
dealer.
A09 Cabin temper-
ature sensor
malfunction
Cabin temperature
sensor defective,
break/short-circuit
in electrical circuit,
cabin temperature
sensor not con-
nected.
Please contact your au-
thorised Webasto Marine
dealer.
A10 Malfunction
- cold water
temperature
Water temperature
sensor defective or
break/short-circuit
in electrical circuit.
Please contact your au-
thorised Webasto Marine
dealer.