SmarTemp Control 3.0 Installation - Operating Instructions
7
Definitions
Default
Value
Mode
Air Heater:
Mode changes the operation of the heater between heat mode and ventilation
mode. Status indicator lights will illuminate red for heat mode and blue for
ventilation mode (air heaters only) when the selected mode is active.
Heat Mode
Coolant heater:
Two modes are possible:
Auto mode enables the pre-defined timer programs. Manual ON/OFF
functionality is still possible while in this mode.
Manual Mode allows the heater to be operated via the Webasto button on
the SmarTemp Control fx 3.0. While in Manual Mode, all Auto Mode
functionality is permanently disabled.
Note: While in manual mode the heater will continue to operate based on the
predefined “Duration” set by the user. See “Duration” for further detail.
Manual
Mode
Timer
Air Heater:
User can select a specific day, time, and heater runtime up to 7 days in the
future. Be aware this is a one-occurrence timer requiring the user to turn the
timer “ON” again after each scheduled timer use.
When selecting timer, a sub-menu will appear (Edit, On, and Off). To modify
timer settings, select “edit”. Select the day, time, and heater runtime using the
rotary knob and the selection button. Settings are saved each time the selection
button is pressed. If the timer function will be used regularly for next day
startups, the “ANY” setting can be used in place of the day of the week. With
this set, the timer will disregard the day setting and start during the next 24-
hour period based on the time selected. The “ANY” setting is located in the
list of days between Saturday and Sunday.
OFF
Coolant Heater:
There are a maximum of 4 timed events per day, and up to 28 timed events per
week.
Note: Timers are only active in Auto mode.
Note: To turn a specific timer off permanently select “off”.
Duration
Air Heaters:
Duration allows for the selection of continuous heater operation or timed
operation. The heater runtime can be set to run for between 30 minutes to 14
hours, in 30-minute increments.
IMPORTANT: Timed duration is not to be mistaken for Timer functionality. The
duration times above are used when turning the heater on manually. i.e. set
the heater duration for 8 hours before heading to bed.
Note: If timed operation is selected 10 hours is default.
Continuous
Coolant Heaters:
Coolant heaters have a minimum run-time of 10 minutes and a maximum of
120 minutes. This can be set in increments of 10 minutes.
Note: While in manual mode the heater will continue to operate based on the
predefined “Duration” set by the user. See “Duration” for further detail.
Language
Language changes between English, Spanish, and French. English

Questions and Answers: