Check:
1) Gas line-to-manifold connections.
WARNING: If there is a leak at connection (1), retighten the fi tting with a wrench and recheck for leaks with soap and
water solution.
If a leak persists after re-tightening the fi tting, turn OFF the gas. DO NOT OPERATE THE GRILL. Contact the Customer
Service Representative in your area using the contact information on our web site. Log onto www.weber.com
®
.
2) Regulator to cylinder connection.
3) Hose to regulator connection.
4) Valves to manifold connections.
WARNING: If there is a leak at connections (2, 3, or 4), turn OFF the gas. DO NOT OPERATE THE GRILL. Contact the
Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.
com
®
.
When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.