QUICK REFERENCE OF PARAMETERS, ALARMS AND FAULTS
Param. Description Adjustable Range Factory Setting Prop.
P264 DI2 Input Function 0 = Not Used
1 = Run/Stop
2 = General Enable
3 = Quick Stop
4 = Foward Run
5 = Reverse Run
6 = Start
7 = Stop
8 = Direction of Rotation
9 = LOC/REM
10 = JOG
11 = Accelerate E.P.
12 = Decelerate E.P.
13 = Multispeed
14 = 2nd Ramp
15 to 17 = Not Used
18 = No Ext. Alarm
19 = No Ext. Fault
20 = Reset
21 to 23 = Not Used
24 = Disab.FlyStart
25 = Not Used
26 = Progr. Off
27 to 31 = Not Used
32 = 2nd Ramp Multispeed
33 = 2nd Ramp Increase E.P.
34 = 2nd Ramp Decrease E.P.
35 = 2nd Ramp FWD Run
36 = 2nd Ramp REV Run
37 = Turn ON / Ac. E.P.
38 = De. E.P. / Turn OFF
39 = Stop
40 = Safety Switch
41 = Application Function 1
42 = Application Function 2
43 = Application Function 3
44 = Application Function 4
45 = Application Function 5
46 = Application Function 6
47 = Application Function 7
48 = Application Function 8
49 = Enable Fire Mode
50 = PID Manual / Automatic
51 to 54 = Not Used
55 = Run/Stop with Line Start Lockout
8 cfg