IE-CS(T)-2TX-xRS232/485 Initial IP Address Configuration
3-5
8. Type m and then press Enter to return to the main menu.
9. Type s and then press Enter to Save/Restart the system.
10. Type y and then press Enter to save the new IP address and restart the IE-CS(T)-2TX-xRS232/485.
Serial Console (19200, n, 8, 1)
You may use the RS-232 console port to set up the IP address for the IE-CS(T)-2TX-xRS232/485. We recommend using
Hyper Terminal Program, which is already installed under Windows XP operating system.although other similar utilities
may also be used.
ATTENTION
The Serial Console is serial port 1 of the IE-CS(T)-2TX-2RS232/485 and it is the DB9 serial port (in RS-232
mode) of the IE-CS(T)-2TX-1RS232/485.
Before you start to configure the IE-CS(T)-2TX-xRS232/485 via serial console, turn off the power and connect
the serial cable from the IE-CS(T)-2TX-xRS232/485 to your computer’s serial port.
1. Connect the IE-CS(T)-2TX-xRS232/485’s serial port 1 directly to your computer’s male RS-232 serial port.
2. From the Windows desktop, click Start –>
Programs -> Accessories -> Communications -> Hyper
Terminal.