EasyManua.ls Logo

weintek MT-8150X - User Manual

weintek MT-8150X
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
MT-600/8000 series
MT-615X / MT-8150X
Installation Instruction
1.0 Installation and Startup Guide
Install Environment
Where
Used
The MT-600/8000 Series is designed for industrial. The temperature range of operating
is from 32 to 113 °F (0 to 45 °C) , as majority of industrial environments. It may not
be suitable for using in certain outdoor applications. Please consult the factory for
advised usage in outdoor applications.
NEMA
Rating
The MT-600/8000 Series front bezel is NEMA 4 rated. When installed properly in a
NEMA 4 panel, the NEMA 4 rating of the panel will not be compromised. This means
that fluids will not enter the panel during wash downs.
Electrical
Environment
The MT-600/8000 Series has been tested to conform to European CE requirements.
This means that the circuitry is designed to resist the effects of electrical noise. This
does not guarantee noise immunity in severe cases. Proper wire routing and
grounding will insure proper operation.
Mechanical
Environment
Avoid installing units in environments where severe mechanical vibration or shocks
are present.
2.0 Installation Instructions
2.1 Mounting Instructions
2.1.1 Location Considerations
Care should be taken when locating equipment behind the unit to ensure that AC power wiring, PLC
output modules, contactors, starters and relays, and any other source of electrical interference are located
away from the back of the unit.
Particular note should be taken to the position of variable speed drives and switching power supplies.
Their input and load cables should be screened to a central star earth point.
Question and Answer IconNeed help?

Do you have a question about the weintek MT-8150X and is the answer not in the manual?

Summary

Installation and Startup Guide

Install Environment

Details the recommended environment for operating the MT-600/8000 series, including temperature and suitability.

Where Used

Specifies the operating temperature range for the MT-600/8000 Series, suitable for industrial environments.

NEMA Rating

Describes the NEMA 4 rating of the front bezel and its implications for panel protection during wash downs.

Electrical Environment

Explains the MT-600/8000 Series' conformity to European CE requirements for electrical noise resistance.

Mechanical Environment

Advises against installing units in environments with severe mechanical vibration or shocks.

Installation Instructions

Mounting Instructions

Details guidelines and considerations for properly mounting the unit, including panel depth and clearances.

Location Considerations

Provides advice on locating equipment behind the unit to avoid electrical interference.

Making a NEMA-4 Mounting

Instructions for panel mounting to achieve NEMA-4 specifications, including clamp usage and torque.

Environmental Considerations

Highlights environmental factors to avoid, such as explosion hazards, rapid temperature variations, and humidity.

Power Connections

Covers power requirements, fusing, high voltage precautions, and emergency stop recommendations.

Grounding Requirements

Specifies chassis grounding and DC ground connection requirements for proper system grounding.

CE Requirements

Outlines compliance with EMC directives and susceptibility to electrical interference.

Safety Guidelines

Presents recommended installation practices and procedures for safe system design and operation.

Communications Connections

Connector COM1 [RS232], COM2 [RS232]

Details cable requirements and pin assignments for COM1 and COM2 RS-232 ports.

Connector COM1[RS485], COM3[RS485] and COM3[RS232]

Describes COM ports for RS-485 and RS-232 connections to controllers.

USB Host port

Information on the USB 2.0 Host interface for connecting peripherals like mice and flash drives.

Connecter Wire

Wiring diagrams and color codes for Ethernet and serial communication cables.

Dip Switch

Dip Switch Settings

Configuration options via DIP switches for modes like Reserve, Hide MT8000 Setting Bar, and Power Switch.

Limited Liability Warranty

Warranty Coverage

Details the limited liability warranty for Weintek products, excluding damage from misuse or unauthorized modifications.

CE Requirements

EU Directives and Compatibility

Lists EU directives for electromagnetic compatibility and safety standards met by the MT-600/8000 Series.

Specifications

Hardware Specification

Technical hardware details for MT615X and MT8150X models, including display, touch panel, and ports.

General Specification

General technical specifications covering power, CE compliance, resistance, temperature, and dimensions.

Dimensions of MT-615 X; MT-8150 X

Unit Dimensions and Views

Diagrams showing top, side, front, rear, and bottom views with key dimensions and cutout details.

Component Identification

Labels and descriptions for various ports and features on the unit, including IDE, USB, Ethernet, and COM ports.

Overview

The MT-600/8000 series, including models MT-615X and MT-8150X, are industrial human-machine interfaces (HMIs) designed for use in various industrial environments. These devices are built to provide a user-friendly interface for controlling and monitoring industrial processes.

Function Description

The MT-600/8000 series HMIs offer a range of functionalities to facilitate industrial control and monitoring. They feature touch-sensitive displays for intuitive interaction, allowing users to navigate through various screens, input data, and trigger actions. The devices support trend graphs, analog meters, bar graphs, numeric entry, switch lamps, and animation for comprehensive data visualization. Popup windows, True Type Fonts, and audio capabilities enhance the user experience. For system management, they include features like security, alarms, data block management, and hardware expansion. Communication is a core strength, with support for multiple PLCs and various communication protocols. The "Touch It, Communication Becomes Easy" slogan highlights their ease of use in connecting with control systems.

Important Technical Specifications

Hardware Specifications (MT615X / MT8150X):

  • Display: 15.0" TFT with 65,536 colors.
  • Brightness: 350 cd/m².
  • Contrast Ratio: 550:1.
  • Resolution: 1024 x 768 dots.
  • Backlight: CCFLx2, with a life time of 50,000 hr. min.
  • Touch Panel: 4-wire resistive type, with an accuracy of Active Area Length(X)±2%, Width(Y)±2%.
  • Surface Hardness: 4H.
  • I/O Ports:
    • COM1 (RS-232/RS-485 2W/4W)
    • COM2 (RS232)
    • COM3 (RS-232/RS-485 2W)
    • 1 Ethernet port (10/100 Base-T)
    • 2 USB Host ports
    • Audio Line Out x 1, MIC In x 1
    • Video Input Port: NTSC/PAL RCA x 2 (V2 Only) (MT8150X only)
  • Processor: x86 500MHz processor.
  • Storage: 256MB D.O.M.
  • DRAM: 256MB on board DDR-400MHz SDRAM.
  • SD Card Slot: Supports SD/SDHC.
  • RTC: Built-in (CR2032 3V lithium battery).

General Specifications:

  • Input Power: 24±10% VDC (21.6~26.4VDC) (Power Isolator Inside).
  • Power Consumption: 1.6 A@24VDC.
  • Isolated Power Supply: Built-in.
  • CE/FCC Compliance: EN 55022: 1998+A1:2000+A2: 2003 Class A, EN 61000-3-2: 2000+A2: 2005, EN 61000-3-3: 1995+A1:2001, EN 55024: 1998+A1:2001+A2: 2003.
  • Voltage Resistance: 500VAC (1 min.).
  • Isolation Resistance: Exceed 50MΩ at 500VDC.
  • Vibration Endurance: 10 to 25 Hz (X,Y,Z direction 2G 30minutes).
  • Protection Structure: IP65 front panel (O ring seal).
  • Storage Temperature: -20~60°C (-4° ~ 140°F).
  • Operating Temperature: 0~45°C (32°~ 113°F).
  • Operation Humidity: 10-90% RH (non-condense).
  • Enclosure: Aluminum.
  • Dimensions WxHxD: 366 x 293 x 55mm.
  • Panel Cutout Dimension: 352 x 279 mm.
  • Weight: Approx. 2.9 kg.
  • Operating System: Windows CE.net 5.0 (MT615X) / EB8000 V4.1.0 or Newer (MT8150X).

Usage Features

Installation Environment: The MT-600/8000 Series is designed for industrial use, with an operating temperature range of 0 to 45 °C (32 to 113 °F). While primarily for indoor use, consultation with the factory is advised for outdoor applications. The front bezel is NEMA 4 rated, ensuring protection against fluids when properly installed in a NEMA 4 panel. The devices are tested to conform to European CE requirements, indicating resistance to electrical noise, though proper wire routing and grounding are crucial for optimal operation. Users should avoid installing units in environments with severe mechanical vibration or shocks.

Mounting: The unit can be mounted into panels with a depth of 4" (105mm). A clearance of 1" (25mm) around the sides is recommended for mounting hardware and cable connections. The unit is secured using clamps provided with the product, tightened in an even pattern to achieve a waterproof effect and prevent panel deformation. Screw torque for clamping is 2.6~3.5 lbf.in. For VESA mounting, there are 4 holes on the back panel for M4 P0.7mm screws, shorter than 8.0mm, with a torque of 2.6 lbf.in. Over-tightening mounting clamps should be avoided. To meet NEMA-4 specifications, all supplied mounting clamps must be used, and the panel cannot flex more than 0.010”.

Environmental Considerations: These HMIs are intended for indoor use as built-in displays. It's crucial to ensure correct installation and adherence to operating limits. They should not be operated in areas with explosion hazards due to flammable gases, vapors, or dusts. Installation in environments with rapid temperature variations or high humidity, which can cause condensation, should also be avoided.

Power Connections: The MT-600/8000 series operates on DC power only, with a specified voltage range of 24±10% Volts DC. The internal power conditioning circuitry uses a switching power supply, with a peak starting current up to 2A. If the display does not power on within 5 seconds, power should be removed, and wiring checked. An internal fuse protects against incorrect DC power polarity and over-voltage conditions (though not guaranteed for over-voltage). DC voltage sources must provide proper isolation from main AC power. A hard-wired EMERGENCY STOP is recommended for any system using the MT-600/8000 to comply with ICS Safety Recommendations. It is advised not to power the HMI and inductive DC loads from the same power supply. Wire lengths should be minimized (Max 1600' shielded, 1000' unshielded) and run in pairs. AC, high energy, and rapidly switching DC wiring should be kept separate from signal wires. Ungrounded DC supplies should be equipped with a resistor and capacitor in parallel to earth ground for static and high-frequency dissipation. After turning the device off, a 10-second wait is recommended before turning it on again to prevent damage or sound output issues.

Grounding Requirements: Chassis ground must be used. While DC ground is not directly coupled to Earth ground internally, if necessary, an earth connection should be made from the power supply return point to a central star earth point. Ground conductors should be as short and large as possible. For CE compliance and reduced susceptibility to electrical interference, a separate #14 AWG ground wire should be run from the chassis ground terminal of the power connector directly to the central star earth connection point.

Communication Connections: The units feature multiple communication ports (COM1, COM2, COM3) supporting RS232, RS485, and RS422 protocols. Cable lengths should be restricted to less than 500' (150m) for RS485/422 devices and 50' (15m) for RS232 devices to avoid communication problems. Shielded cables are recommended for long lengths or noisy environments. Cables should not be run next to AC power lines or sources of electrical noise. The COM light on the front of the HMI will illuminate with each Ethernet communication. The USB Host port supports USB mouse, keyboard, USB Flash Drive, and printer. External hard drives require an external power supply, and the USB port should not be used to charge external devices.

Maintenance Features

Limited Liability Warranty: Weintek products, including the isolated power supply, are covered by a limited liability warranty against material and workmanship defects. This warranty does not apply if the product fails due to shipping damage, handling, storage, accident (natural or man-made), misuse (including incorrect setup, wiring, current leakage, or incorrect input power), maintenance not conforming to instructions, modification, or if the serial number has been defaced or removed.

Safety Guidelines: The manual provides recommended installation practices and procedures, emphasizing that these are guidelines as applications vary. It warns system designers that devices in Controller systems can fail, creating unsafe conditions, and electrical interference in the HMI could lead to equipment start-up, potentially causing property damage or physical injury. It advises precautions for programmable control systems, including the use of an emergency stop function independent of the programmable controller, especially where operators are exposed to machinery. Consideration should also be given to electromechanical overrides or redundant means for starting and interrupting cycles, and locks or other means to ensure only authorized personnel can change programs. These recommendations align with NEMA ICS 3-304 Control Standards. To conform with ICS Safety Recommendations, checks should be placed in the controller to ensure that all writable registers controlling critical plant parts have limit checks built into the program, with an out-of-limit safe shutdown procedure.

weintek MT-8150X Specifications

General IconGeneral
Brandweintek
ModelMT-8150X
CategoryTouch Panel
LanguageEnglish

Related product manuals