Part Number STH098 06/19 147
REFRIGERANT PURGING REQUIREMENTS
NOTE: Country and Local Codes for removal and processing
of this refrigerant must always take precedence over these
procedures.
Minimum of 10 feet from building, verify wind
direction will not introduce refrigerant into building
Verify refrigerant does not enter buildings through
intake air vents
Although not required hydrocarbon refrigerants can be
recovered, instead of venting to the atmosphere.
Purge system with dry nitrogen to displace any trapped
propane.
DANGER
Disconnect all electric power to the system. Shorting
electrical wires to refrigeration tubing may result in an
explosion.