EasyManuals Logo

Welbilt Manitowoc NEO UDP0080A User Manual

Welbilt Manitowoc NEO UDP0080A
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
Part Number STH098 06/19 37
REMEDIAL CLEANING
This procedure can be performed between the bi-annual
detailed descaling and sanitizing cycles. This procedure
does not require removing the ice from the bin.
Step 1 Press the On/Off button after ice falls from the
evaporator at the end of a Harvest cycle. Or, press the On/
Off button and allow the ice to melt off the evaporator.
,
Caution
Never use anything to force ice from the evaporator.
Damage may result.
n
Warning
Wear rubber gloves and safety goggles (and/or face
shield) when handling Ice Machine Cleaner/Descaler
or Sanitizer.
Step 2 To start a cycle, press the Clean button. Water
will flow through the water dump valve and down the
drain. Wait until the water trough refills, then add the
proper amount of ice machine cleaner/descaler to the
water trough.
Model Amount of Cleaner/Descaler
Part Number 9405463
UDP0140 2 ounce (60 ml)
UDP0240 5 ounces (150 ml)
UDP0310 5 ounces (150 ml)
Wait until the cycle is complete (approximately 22
minutes) then press the On/Off button.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Welbilt Manitowoc NEO UDP0080A and is the answer not in the manual?

Welbilt Manitowoc NEO UDP0080A Specifications

General IconGeneral
BrandWelbilt
ModelManitowoc NEO UDP0080A
CategoryIce Maker
LanguageEnglish

Related product manuals