Part Number STH098 06/19 43
Step 5 Wait until the cycle is complete (approximately
22 minutes) then place the toggle switch in the Off
position and disconnect power and water supplies to the
ice machine.
n
Warning
Disconnect electric power to the ice machine at the
electric switch box before proceeding.
Step 6 Remove parts for descaling.
A. Remove Two Thumbscrews and Water Pump
Cover.
B. Remove the Vinyl Hose Connecting the Water
Pump and Water Distribution Tube.
C. Remove Water Pump
Disconnect the water pump power cord.
Loosen the screws securing the pump mounting
bracket to the bulkhead.
Lift the pump and bracket assembly off the mounting
screws.