80 Part Number STH098 06/19
Safety Limit 3
If the freeze time reaches 4 minutes and water is not
sensed (float remains down for 10 continuous seconds) the
ice machine stops.
Safety Limit 3 is bypassed on the initial cycle (manual
start or after a full bin/safety limit condition). For all
subsequent cycles if the freeze time reaches 4 minutes
and water is not sensed, the ice machine stops and
initiates a 30 minute delay period. Control board
lights SL#1 and SL#2 along with the touch pad Service
(wrench) light will flash on/off at 1 second intervals.
The ice machine automatically restarts at the end of
the 30 minute delay period and stops flashing the
control board and Service (wrench) lights.
If 100 consecutive failures occur the ice machine stops
and the touch pad Service (wrench) light remains
energized.