4/7/2017 WellSoft Owner’s Manual 25
Water Conditioner Performance & Specifications
Performance & Specifications
Specification WS80 WS100
Maximum Capacity - grains
24,000 35,000
Maximum Compensated Hardness - gpg (mg/L)
70 (1200) 90 (1540)
Maximum Ferrous Iron Reduction - ppm
1
10 10
Minimum pH - standard units
7 7
Water & Ambient Temperature Minimum-Maximum - °F (°C)
40°-120° (4°-49°) 40°-120° (4°-49°)
Water Pressure Minimum - Maximum - psi (bar)
20 (1.4) - 100 (7) 20 (1.4) - 100 (7)
Maximum Flow Rate to Drain During Regeneration
2
gpm
(L/min)
2.0 (7.6) 2.0 (7.6)
Service Flow Rate (@15 psi (1.0 bar)) drop - gpm (L/min)
3
5.5 (20.8) 5.5 (20.8)
Pressure Drop @ 5.5 gpm (22.7 L/min) - psi (bar)
15 (1) 15 (1)
Salt Used
lb (kg)
Water Used
Gallons (Liters)
WS80
Grains (Grams) removed
WS100
Grains (Grams) removed
1.6 (0.7) 14 (53) 7,569 (490) 7,801 (505)
8 (3.6) 23.5 (89) 25,862 (1676) 28,314 (1835)
15 (16.8) 35 (132) 27,792 (1801) 35,910 (2327)
Controller Type
Metered Metered
Electrical Rating
12VAC, 50/60 Hz,
0.015 kW-hr
12VAC, 50/60 Hz,
0.015 kW-hr
Plumbing Connections (NPT)
1 inch male (MNPT) 1 inch male (MNPT)
Minimum Drain Line ID - inch (cm)
5/8 inch (1.6) 5/8 inch (1.6)
Media Tank Size - (ID x Height) - inch (cm)
10.5 x 23 (26.7 x 58.4) 10.5 x 26 (26.7 x 66)
Height - inches (cm)
27.8 (70.6) 31.3 (79.5)
Footprint - inches (cm)
15.9 x 19.1 (40.4 x 48.5) 15.9 x 19.1 (40.4 x 48.5)
Shipping Weight - approx. - lb (kg)
95 (43) 105 (48)
Media Type / Amount
Fine Mesh Resin
0.8 cu.ft. (23L) 1.0 cu.ft. (28L)
For All Models:
Use clean white pellet, cube-style, or solar salt.
Drain Line (Minimum I.D.) 5/8 inch (1.6 cm)
Brine & Rinse total - 0.75 gpm (2.8 L/min)
Brine Draw - 0.25 gpm (0.9 L/min)
Rinse - 0.5 gpm (1.9 L/min)
1
Iron reduction to 0.3 ppm or less. Iron reduction claims limited to 5 ppm in the
state of Wisconsin.
2
Rate of flow must be verified at the end of the drain line.
3
For the purposes of plumbing appliance sizing, only the rated service flow rate
and corresponding pressure loss may be used. Prolonged operation of a water
softener at flow rates exceeding the tested service flow rate of 5.5 gpm (20.8 L/
min) may compromise performance. Intermittent flow rate must not exceed 9.3
gpm (35.2 L/min).
System conforms to NSF/ANSI 44 for the specific performance claims as verified and substantiated by test data.